Customization: | Available |
---|---|
Surface Treatment: | PVC Housing |
Certification: | CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Unipole Conductor Rail system NSP-H Series | |||||
Conductor rail | Aluminium | Copper | |||
Type | H19 | H24 | H32 | H24 | H32 |
Nominal current at 100% DC and 35°C[A] | 150 | 250 - 300 | 320 - 1250 | 500 - 800 | 800 - 1600 |
D.C.resistance at 35°C [Ω/km] | 0.376 | 0.2030.187 | 0.1530.046 | 0.1160.067 | 0.0670.039 |
Impendance at 35°C [Ω/km] | 0.376 | 0.2090.195 | 0.1550.048 | 0.1180.069 | 0.0690.04 |
Support spacing [m] | 1.8 | 1.5 | 1.8 | 1.5 | 1.8 |
Rail length [m] | 4/6 | 4/6 | 4/6 | 4/6 | 4/6 |
Housing length [m] | 3.88/5.88 | 3.88/5.88 | 3.83/5.83 | 3.88/5.88 | 3.83/5.83 |
Max.voltage [V] | 660V | Dielectric strength[KV/mm] | 30-40 | ||
Travelling speed | ≤ 600 m/min | Standard | GB7251.2-2006 | ||
Expansion joint | only required when total length ≥ 200m | ||||
Flame retardant | Class B1-no flaming particles,self-extinguishing | ||||
Permissible ambient temperature | Standard insulation -20C- +70C High temperature insulation -10C- +115C |
Type | Conductor Rail | Cross section (mm2) |
Nominal current (A) |
Leakage-distance (mm) |
Resistance (Ω/km) |
Weight (kg/m) |
LSP-H24-160/250 | Aluminium | 160 | 250 | 45 or 80 | 0.203 | 0.63 |
NSP-H24-180/300 | Aluminium | 180 | 300 | 45 or 80 | 0.187 | 0.71 |
Type | Conductor Rail | Cross section (mm2) |
Nominal current (A) |
Leakage-distance (mm) |
Resistance (Ω/km) |
Weight (kg/m) |
LSP-H32-230/320 | Aluminium | 230 | 320 | 80 | 0.153 | 0.96 |
LSP-H32-285/500 | Aluminium | 285 | 500 | 80 | 0.116 | 1.13 |
LSP-H32-360/630 | Aluminium | 360 | 630 | 80 | 0.087 | 1.38 |
LSP-H32-420/800 | Aluminium | 450 | 800 | 80 | 0.067 | 1.5 |
LSP-H32-550/1000 | Aluminium | 550 | 1000 | 80 | 0.058 | 1.83 |
LSP-H32-600/1250 | Aluminium | 600 | 1250 | 80 | 0.046 | 2.01 |